Fire compartmentation requirements sit at the heart of every UK building's fire strategy. They decide how long a fire stays contained in one part of a building before it can spread.
Get them wrong, and the consequences are severe. That applies to life safety and to legal liability alike.
This guide walks through the fire compartmentation building regulations that apply across the UK. It also covers the legislation added on top since 2017, and what building owners need to check to stay compliant.
At GRJ Contracting, we install and survey fire compartmentation systems across the UK. This article brings the legal picture together, with a look at where specialist contractors like us fit in.
What are fire compartmentation requirements in UK building regulations?
Fire compartmentation requirements exist to slow a fire down. A building is divided into sealed sections so that a fire starting in one part cannot easily reach another.
This buys time. Time for occupants to get out, and time for fire crews to get in.
Building Regulations 2010, Requirement B3
The legal starting point in England is Requirement B3 of Schedule 1 to the Building Regulations 2010. It covers fire spread through a building's structure.
B3 does not give specific numbers itself. It sets the legal duty. The detail on how to meet that duty sits in supporting guidance.
Approved Document B and How Compartmentation Works
Approved Document B explains how to satisfy B3 in practice. It covers means of escape, internal fire spread, external fire spread and access for fire crews.
Compartmentation means using fire-resisting walls, floors and doors to break a building into separate fire cells. Each cell is designed to hold a fire for a set period.
During that time, smoke and flame should not pass into the next compartment. Any gap in that boundary has to be sealed to the same standard as the wall or floor around it.
This is where firestopping and cavity barrier work becomes essential. It is a large part of what GRJ Contracting installs on site.
Fire Resistance Periods and Compartment Size Limits
Fire compartmentation matters because it contains fire, heat and toxic smoke at the point of origin instead of them spreading freely through a building. This protects escape routes and gives occupants the time they need to evacuate safely. It also gives fire services a better chance of bringing the fire under control before it spreads further.
Beyond life safety, compartmentation helps preserve the structural integrity of a building. By limiting how far fire can spread and how much heat builds up in any one area, it reduces the risk of structural collapse. It can significantly limit the extent of fire and smoke damage across the building as a whole.
BS 9999 as an Alternative Compliance Route
Approved Document B is not the only route to compliance. BS 9999 offers a risk-based alternative through fire engineering analysis.
It covers compartmentation, escape routes, detection and suppression across the whole life of a building. Architects and fire engineers often use it on complex buildings where the prescriptive guidance does not fit well.
UK legislation that adds to fire compartmentation requirements
Building Regulations and Approved Document B set the technical baseline. Since the Grenfell Tower fire in 2017, several pieces of legislation have added extra duties on top.
These do not always change the fire resistance numbers themselves. They change who is responsible, how compartmentation gets checked, and what happens if it fails.
Regulatory Reform (Fire Safety) Order 2005
This Order is the main piece of legislation governing fire safety once a building is occupied. Where Approved Document B deals with design and construction, this Order deals with ongoing management.
It places a duty on a "responsible person" to keep fire doors, fire stopping and cavity barriers in good working order. This duty runs for as long as the building is in use.
Older buildings often need existing compartmentation upgraded or repaired to meet current standards. This is usually where remediation contracts come in.
Fire Safety Act 2021
The Fire Safety Act 2021 amended the 2005 Order to remove any doubt about what falls within scope. It confirmed that a building's structure, external walls, cladding, balconies and flat entrance doors all count.
This closed a gap that had allowed some buildings to treat external walls as outside the reach of fire risk assessments. It also introduced new duties, including sharing fire safety information with residents.
Blocks of flats above 11 metres in height now need regular fire door checks.
Fire Safety (England) Regulations 2022
These regulations sit underneath the Fire Safety Act 2021. They turn some of its principles into specific operational duties.
They set out concrete requirements for multi-occupied residential buildings. That includes checking fire doors on a fixed schedule and giving residents clear information about the compartment lines protecting them.
Building Safety Act 2022
The Building Safety Act 2022 is the biggest change in this area for a generation. It was written in direct response to Grenfell.
It reshapes how compartmentation is designed, checked and maintained on higher-risk buildings. It also created the Building Safety Regulator, with stronger enforcement powers.
The Golden Thread and Fire Safety Records
The golden thread is one of the most practical changes from the Building Safety Act. It is a digital record kept for the life of a building.
It includes architectural drawings, fire safety strategies, material specifications and a log of changes made during construction or afterwards. Before this requirement existed, details about compartmentation could easily get lost.
Independent survey reports feed directly into this record. They give building owners something solid to point to.
Gateway Points 1, 2 and 3
Higher risk buildings now go through gateway checks at key stages of a project. Gateway 1 happens before planning permission is granted.
Gateway 2 happens before construction starts. Gateway 3 happens before the building can be occupied.
Compartmentation strategy gets scrutinised at each checkpoint, rather than reviewed only once at the end.
Section 156 and Fire Risk Assessments
Section 156 of the Building Safety Act 2022 amends the 2005 Order again. This time it tightens how fire risk assessments must be recorded.
Responsible persons now need formal, documented records of fire safety arrangements. Informal notes are no longer enough.
This applies broadly across non-domestic premises and the common parts of residential buildings. It is not limited to the tallest blocks.
Do higher-risk buildings have extra compartmentation requirements?
Higher-risk buildings face a stricter version of the same rules. There is also a whole extra layer of oversight that smaller buildings do not have to deal with.
What Counts as a Higher-Risk Building
A building counts as higher risk in England if it is at least 18 metres tall or has at least seven storeys. It also needs to contain two or more residential units.
Hospitals and care homes of that height fall within scope too, even though they are not residential in the usual sense.
Registration with the Building Safety Regulator
Existing buildings that meet this definition had to be registered with the Building Safety Regulator by October 2023. Registration is not a one-off formality.
It ties the building into ongoing oversight. It gives the regulator visibility over the building's safety case going forward.
Building Assessment Certificates and The Safety Case
From April 2024, higher-risk buildings need a Building Assessment Certificate. The Principal Accountable Person has to submit a safety case to the regulator.
That safety case has to demonstrate that compartmentation is sound and properly documented. It also has to show the compartmentation is being actively maintained, not just correct at the point of construction.
A third-party accredited survey gives building owners independent evidence to support that case.
Without regular checks, small defects such as a propped-open fire door or a partially sealed penetration can persist unnoticed. Gradually, they weaken the building's overall fire protection.
What Happens if Compartmentation Requirements Aren't Met?
Failing to meet fire compartmentation requirements is not just a paperwork issue. It carries real enforcement risk, and real safety risk for anyone inside the building.
Local Authority and BSR Enforcement Powers
Local authorities and the Building Safety Regulator both have the power to take enforcement action. On higher-risk buildings, the regulator can step in directly rather than leaving it to the local council.
Responsible Person Duties Under The RRFSO
Under the 2005 Order, the responsible person carries the legal duty to keep compartmentation working. That covers fire doors, cavity barriers and any penetration through a compartment wall or floor.
If a fire risk assessment identifies a failure, the responsible person has to act on it. That usually means bringing in a specialist contractor for remediation work.
Fire Door Checks and Resident Information Duties
In blocks of flats above 11 metres, fire doors now need regular checks. This applies under the Fire Safety Act 2021 and the 2022 Regulations.
Residents also have a right to information about the fire safety measures in their building. That includes how the compartmentation strategy is meant to protect them.
Fire Compartmentation Regulations for the Rest of the UK
The golden thread is one of the most practical changes from the Building Safety Act. It is a digital record kept for the life of a building.
It includes architectural drawings, fire safety strategies, material specifications and a log of changes made during construction or afterwards. Before this requirement existed, details about compartmentation could easily get lost.
Independent survey reports feed directly into this record. They give building owners something solid to point to.
How GRJ Contracting helps you stay compliant
Fire compartmentation requirements used to sit almost entirely within Approved Document B. That is no longer true.
The technical guidance still sets the baseline. But the Fire Safety Act, the Fire Safety Regulations and the Building Safety Act have all added duties around recording, checking and proving that compartmentation actually works.
GRJ Contracting has been detailing, supplying and installing passive fire protection systems across the UK since 2007. Our services cover structural steel fire protection, fire compartmentation, fire doors, firestopping and cavity barriers.
We hold Kiwa IFC, ASFP and ISO 9001 accreditation. Our surveying arm, GRJ Surveying, carries out compartmentation and structural steel surveys that give building owners a clear picture of where their building stands.
If you manage a building and need help meeting fire compartmentation requirements, get in touch with GRJ Contracting. Our team will talk through what your building needs.